HEAT TREATMENT EQUIPMENTS

INCERTECH’s Heat Treatment Equipment has beenrobustly constructed to provide power to electrical resistance heaters at 65 /85 volts, suitable for site and shop working. The output from the unit is splitinto six individual heating circuits for temperature control.

ICT50 – 50 kva

ICT65 – 65 kva


ICT50 – 50 kva – 6 channelheat treatment equipment without programmers

Each output circuit has 8.1 kW of power,which is sufficient capacity for 3 standard ceramic pads rated at 2.7 kW or 2standard ceramic pads rated at 3.6 kW connected in parallel. Each of the sixcircuits may be controlled individually using either energy regulators inmanual mode or using external programmer in automatic mode to gain control overrates of heating and cooling as well as soak conditions.

 

Primary Input:

380/415/440 Volts

Output:

65 Volts / 85 Volts or both as requested

 Auxiliary Supply

2 x 220 Volts or 110 Volts as requested

 


ICT50P – 50 kva – 6channel heat treatment equipment with programmers

Each output circuit has 8.1 kW of power,which is sufficient capacity for 3 standard ceramic pads rated at 2.7 kW or 2standard ceramic pads rated at 3.6 kW connected in parallel. Each of the sixcircuits may be controlled individually using either energy regulators inmanual mode or using inbuilt 6 individual programmer for each channel inautomatic mode to gain control over rates of heating and cooling as well assoak conditions.

 

Primary Input:

380/415/440 Volts

Output:

65 Volts / 85 Volts or both as requested

 Auxiliary Supply

2 x 220 Volts or 110 Volts as requested

 


ICT65 – 65 kva – 6 channelheat treatment equipment without programmers

 

The output from theunit is split into six individual heating circuits for temperature control.Each output circuit has 10.8 kW of power, which is sufficient capacity for 4standard ceramic pads rated at 2.7 kW or 3 standard ceramic pads rated at 3.6kW connected in parallel. Each of the six circuits may be controlledindividually using either energy regulators in manual mode or using externalprogrammer in automatic mode to gain control over rates of heating and coolingas well as soak conditions.

Primary Input:

380/415/440 Volts

Output:

65 Volts / 85 Volts or both as requested

 Auxiliary Supply

2 x 220 Volts or 110 Volts as requested

 

 


ICT65P - 65 kva – 6channel heat treatment equipment with programmers

The output from theunit is split into six individual heating circuits for temperature control.Each output circuit has 10.8 kW of power, which is sufficient capacity for 4standard ceramic pads rated at 2.7 kW or 3 standard ceramic pads rated at 3.6kW connected in parallel. Each of the six circuits may be controlledindividually using either energy regulators in manual mode or using inbuilt 6individual programmer for each channel in automatic mode to gain control overrates of heating and cooling as well as soak conditions.

Primary Input:

380/415/440 Volts

Output:

65 Volts / 85 Volts or both as requested

 Auxiliary Supply

2 x 220 Volts or 110 Volts as requested

 

Specifications –ICT65 power source

  • Length: Approx. 800 mm
  • Width: Approx. 800 mm
  • Height: Approx. 900 mm
  • Weight: Approx. 465 kg
  • Material: 3.5 mm angle frame & 14/16 gauge steel painted cabinet
  • Handling: Four top lifting eye lugs and forklift access.

Inputs:

  • Voltage: 380-415-440, 3 Phase
  • Current: 100 amp
  • Power: 75 KVA Isolated Copper Wound
  • Frequency: 60 Hz / 50 Hz

Output Per Zone:

  • Zones: 6
  • Voltage: 65 or 85 VAC, single phase
  • Current: 194 amps @ 65 V or 152 amps 85V
  • Power: 12.5 KVA
  • Activation: 200 amp contactor
  • Control per zone: Digital temperature control via Programmer / Controller

Control Circuit:

  • Voltage: 230 VAC, single phase
  • Current: 5 amp circuit breaker
  • Power: 1.2 KVA winding on power transformer
  • Auxiliary: 230 VAC supply, single phase

6 Channel Temperature Programmer/Controller

  • Temperature Range: 0-2000°F or 0-1200°C
  • Thermocouple: Type “K”

Protection:

  • 230-VAC Control Circuit: 5 amp circuit breaker
  • Heater Power: Isolation contactor for each zone
  • Console Power: 100 amp main circuit breaker
  • Power Transformer: 160°C thermal protection

Cooling fan: 208 CFM